Home / Clinician Tools / Ejection Fraction (Teichholz Method)

Ejection Fraction (Teichholz Method) - Scientific Formula

Cardiology Equation

Standard Calibration Equation:

Volume = [7 * LVID³] / [2.4 + LVID] | EF (%) = (EDV - ESV) / EDV * 100

Accuracy Bounds & Limits:

While mathematical calculators evaluate demographic models, extreme variance (hyperthyroidism, dialysis cases, muscular bodybuilders, pregnancy) can trigger output errors. Weight and clearance assessments must follow separate personalized titration grids.